Large Ammonia Refrigeration System with Full Heat Reclaim
The first stage of commissioning has been completed on a large industrial food processing facility that includes heat reclaim from the refrigeration compressors oil cooling and condenser/ de superheater to provide a heating source for evaporator defrost and space heating .
ISECO worked in close consultation with the client , their specialist equipment providers and the final developer to define the refrigeration concept and provide performance design level documentation and specifications so the successful Contractor could complete the design and installation. The medium temperature capacity for the ammonia /glycol system was 5100 kW and there is another 170 kW for low temperature freezer and specialist crust freezers running on CO2/glycol cascade.